CLREX

Clear Exclusive clears the local monitor of the executing PE.

313029282726252423222120191817161514131211109876543210
11010101000000110011CRm01011111
op2Rt

CLREX {#<imm>}

// CRm field is ignored

Assembler Symbols

<imm>

Is an optional 4-bit unsigned immediate, in the range 0 to 15, defaulting to 15 and encoded in the "CRm" field.


Internal version only: aarchmrs v2024-03_relA, pseudocode v2024-03_rel, sve v2024-03_rel ; Build timestamp: 2024-03-26T09:45

Copyright © 2010-2024 Arm Limited or its affiliates. All rights reserved. This document is Non-Confidential.