FMOV (scalar, immediate)

Floating-point move immediate (scalar). This instruction copies a floating-point immediate constant into the SIMD&FP destination register.

Depending on the settings in the CPACR_EL1, CPTR_EL2, and CPTR_EL3 registers, and the current Security state and Exception level, an attempt to execute the instruction might be trapped.

313029282726252423222120191817161514131211109876543210
00011110ftype1imm810000000Rd
MSimm5

Half-precision (ftype == 11)
(FEAT_FP16)

FMOV <Hd>, #<imm>

Single-precision (ftype == 00)

FMOV <Sd>, #<imm>

Double-precision (ftype == 01)

FMOV <Dd>, #<imm>

if ftype == '10' || (ftype == '11' && !IsFeatureImplemented(FEAT_FP16)) then UNDEFINED; integer d = UInt(Rd); constant integer datasize = 8 << UInt(ftype EOR '10'); bits(datasize) imm = VFPExpandImm(imm8, datasize);

Assembler Symbols

<Hd>

Is the 16-bit name of the SIMD&FP destination register, encoded in the "Rd" field.

<imm>

Is a signed floating-point constant with 3-bit exponent and normalized 4 bits of precision, encoded in the "imm8" field. For details of the range of constants available and the encoding of <imm>, see Modified immediate constants in A64 floating-point instructions.

<Sd>

Is the 32-bit name of the SIMD&FP destination register, encoded in the "Rd" field.

<Dd>

Is the 64-bit name of the SIMD&FP destination register, encoded in the "Rd" field.

Operation

CheckFPEnabled64(); V[d, datasize] = imm;


Internal version only: aarchmrs v2024-03_relA, pseudocode v2024-03_rel, sve v2024-03_rel ; Build timestamp: 2024-03-26T09:45