The ERRCRICR1 characteristics are:
Critical Error Interrupt configuration register.
This register is present only when (the Critical Error Interrupt is implemented or the implementation does not use the recommended layout for the ERRIRQCR registers) and interrupt configuration registers are implemented. Otherwise, direct accesses to ERRCRICR1 are RES0.
ERRCRICR1 is implemented only as part of a memory-mapped group of error records.
ERRCRICR1 is a 32-bit register.
31 | 30 | 29 | 28 | 27 | 26 | 25 | 24 | 23 | 22 | 21 | 20 | 19 | 18 | 17 | 16 | 15 | 14 | 13 | 12 | 11 | 10 | 9 | 8 | 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
RES0 |
Reserved, RES0.
31 | 30 | 29 | 28 | 27 | 26 | 25 | 24 | 23 | 22 | 21 | 20 | 19 | 18 | 17 | 16 | 15 | 14 | 13 | 12 | 11 | 10 | 9 | 8 | 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
DATA |
Payload for the message signaled interrupt.
The reset behavior of this field is:
31 | 30 | 29 | 28 | 27 | 26 | 25 | 24 | 23 | 22 | 21 | 20 | 19 | 18 | 17 | 16 | 15 | 14 | 13 | 12 | 11 | 10 | 9 | 8 | 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
IMPLEMENTATION DEFINED |
IMPLEMENTATION DEFINED.
If the implementation does not use the recommended layout for the ERRIRQCR registers then accesses to ERRCRICR1 are IMPLEMENTATION DEFINED.
Component | Offset | Instance |
---|---|---|
RAS | 0xEA8 | ERRCRICR1 |
This interface is accessible as follows:
26/03/2024 09:49; 67c0ae5282a7629ba0ea0ba7267b43cd4f7939f6
Copyright © 2010-2024 Arm Limited or its affiliates. All rights reserved. This document is Non-Confidential.