The ERR<n>CTLR characteristics are:
The error control register contains enable bits for the node that writes to this record:
For each bit, if the node does not support the feature, then the bit is RES0. The definition of each record is IMPLEMENTATION DEFINED.
This register is present only when error record n is implemented and error record n is the first error record in the node. Otherwise, direct accesses to ERR<n>CTLR are RES0.
ERR<n>FR contains additional information about the node.
ERR<n>CTLR is a 64-bit register.
63 | 62 | 61 | 60 | 59 | 58 | 57 | 56 | 55 | 54 | 53 | 52 | 51 | 50 | 49 | 48 | 47 | 46 | 45 | 44 | 43 | 42 | 41 | 40 | 39 | 38 | 37 | 36 | 35 | 34 | 33 | 32 |
31 | 30 | 29 | 28 | 27 | 26 | 25 | 24 | 23 | 22 | 21 | 20 | 19 | 18 | 17 | 16 | 15 | 14 | 13 | 12 | 11 | 10 | 9 | 8 | 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
IMPLEMENTATION DEFINED | |||||||||||||||||||||||||||||||
RES0 | WDFI | Bit[14] | CI | CED | WDUI | Bit[10] | WCFI | Bit[8] | WUE | WFI | WUI | Bit[4] | Bit[3] | Bit[2] | IMPLEMENTATION DEFINED | ED |
Reserved for IMPLEMENTATION DEFINED controls. Must permit SBZP write policy for software.
Reserved, RES0.
Fault handling interrupt for Deferred errors on writes enable, with ERR<n>CTLR.WFI.
When enabled by ERR<n>CTLR.{WDFI, WFI}:
WDFI | Meaning |
---|---|
0b0 | When ERR<n>CTLR.WFI == 0, Fault handling interrupt not generated for Deferred errors on writes. When ERR<n>CTLR.WFI == 1, Fault handling interrupt generated for Deferred errors on writes. |
0b1 | When ERR<n>CTLR.WFI == 0, Fault handling interrupt generated for Deferred errors on writes. When ERR<n>CTLR.WFI == 1, Fault handling interrupt not generated for Deferred errors on writes. |
See ERR<n>CTLR.CFI for more information on corrected error events.
The interrupt is generated even if the error syndrome is discarded because the error record already records a higher priority error.
The reset behavior of this field is:
Reserved, RES0.
Fault handling interrupt for Deferred errors enable, with ERR<n>CTLR.FI.
When ERR<n>FR.DFI == 0b10, this control applies to errors on both reads and writes.
When enabled by ERR<n>CTLR.{DFI, FI}:
DFI | Meaning |
---|---|
0b0 | When ERR<n>CTLR.FI == 0, Fault handling interrupt not generated for Deferred errors. When ERR<n>CTLR.FI == 1, Fault handling interrupt generated for Deferred errors. |
0b1 | When ERR<n>CTLR.FI == 0, Fault handling interrupt generated for Deferred errors. When ERR<n>CTLR.FI == 1, Fault handling interrupt not generated for Deferred errors. |
See ERR<n>CTLR.CFI for more information on corrected error events.
The interrupt is generated even if the error syndrome is discarded because the error record already records a higher priority error.
The reset behavior of this field is:
Fault handling interrupt for Deferred errors on reads enable, with ERR<n>CTLR.RFI.
When ERR<n>FR.DFI == 0b11, this field is named RDFI.
When enabled by ERR<n>CTLR.{RDFI, RFI}:
RDFI | Meaning |
---|---|
0b0 | When ERR<n>CTLR.RFI == 0, Fault handling interrupt not generated for Deferred errors on reads. When ERR<n>CTLR.RFI == 1, Fault handling interrupt generated for Deferred errors on reads. |
0b1 | When ERR<n>CTLR.RFI == 0, Fault handling interrupt generated for Deferred errors on reads. When ERR<n>CTLR.RFI == 1, Fault handling interrupt not generated for Deferred errors on reads. |
See ERR<n>CTLR.CFI for more information on corrected error events.
The interrupt is generated even if the error syndrome is discarded because the error record already records a higher priority error.
The reset behavior of this field is:
Reserved, RES0.
Critical error interrupt enable. When enabled, the critical error interrupt is generated for a critical error condition.
CI | Meaning |
---|---|
0b0 |
Critical error interrupt not generated for critical errors. Critical errors are treated as Uncontained errors. |
0b1 |
Critical error interrupt generated for critical errors. |
The reset behavior of this field is:
Reserved, RES0.
Disable generation of corrected error events from error counters.
CED | Meaning |
---|---|
0b0 |
Corrected error events are generated by the error counter or counters. |
0b1 |
Corrected error events are generated when a Corrected error is recorded. |
See ERR<n>CTLR.CFI for more information on corrected error events.
The reset behavior of this field is:
Reserved, RES0.
Error recovery interrupt for Deferred errors on writes enable.
When enabled, the error recovery interrupt is generated for errors recorded as Deferred error on writes.
WDUI | Meaning |
---|---|
0b0 |
Error recovery interrupt not generated for Deferred errors on writes. |
0b1 |
Error recovery interrupt generated for Deferred errors on writes. |
The interrupt is generated even if the error syndrome is discarded because the error record already records a higher priority error.
The reset behavior of this field is:
Reserved, RES0.
Error recovery interrupt for Deferred errors enable.
When ERR<n>FR.DUI == 0b10, this control applies to errors arising from both reads and writes.
When enabled, the error recovery interrupt is generated for all errors recorded as Deferred error.
DUI | Meaning |
---|---|
0b0 |
Error recovery interrupt not generated for Deferred errors. |
0b1 |
Error recovery interrupt generated for Deferred errors. |
The interrupt is generated even if the error syndrome is discarded because the error record already records a higher priority error.
The reset behavior of this field is:
Error recovery interrupt for Deferred errors on reads enable.
When ERR<n>FR.DUI == 0b11, this field is named RDUI.
When enabled, the error recovery interrupt is generated for errors recorded as Deferred error on reads.
RDUI | Meaning |
---|---|
0b0 |
Error recovery interrupt not generated for Deferred errors on reads. |
0b1 |
Error recovery interrupt generated for Deferred errors on reads. |
The interrupt is generated even if the error syndrome is discarded because the error record already records a higher priority error.
The reset behavior of this field is:
Reserved, RES0.
Fault handling interrupt for corrected error events on writes enable.
When enabled, the fault handling interrupt is generated for corrected error events on writes.
WCFI | Meaning |
---|---|
0b0 |
Fault handling interrupt not generated for corrected error events on writes. |
0b1 |
Fault handling interrupt generated for corrected error events on writes. |
See ERR<n>CTLR.CFI for more information on corrected error events.
The interrupt is generated even if the error syndrome is discarded because the error record already records a higher priority error.
The reset behavior of this field is:
Reserved, RES0.
Fault handling interrupt for corrected error events enable.
When ERR<n>FR.CFI == 0b10, this control applies to errors on both reads and writes.
When enabled, the fault handling interrupt is generated for all corrected error events.
CFI | Meaning |
---|---|
0b0 |
Fault handling interrupt not generated for corrected error events. |
0b1 |
Fault handling interrupt generated for corrected error events. |
If the node implements a corrected error counter or counters, and either ERR<n>CTLR.CED is not implemented or ERR<n>CTLR.CED is 0, then a corrected error event is defined as follows:
A corrected error event occurs when a counter overflows and sets a counter overflow flag to 1.
It is UNPREDICTABLE whether a corrected error event occurs when a software write sets a counter overflow flag to 1.
It is UNPREDICTABLE whether a corrected error event occurs when a counter overflows and the overflow flag was previously set to 1.
Otherwise, a corrected error event occurs when the error record records an error as a Corrected error.
The interrupt is generated even if the error syndrome is discarded because the error record already records a higher priority error.
The reset behavior of this field is:
Fault handling interrupt for corrected error events on reads enable.
When ERR<n>FR.CFI == 0b11, this field is named RCFI.
When enabled, the fault handling interrupt is generated for corrected error events on reads.
RCFI | Meaning |
---|---|
0b0 |
Fault handling interrupt not generated for corrected error events on reads. |
0b1 |
Fault handling interrupt generated for corrected error events on reads. |
If the node implements a corrected error counter or counters, and either ERR<n>CTLR.CED is not implemented or ERR<n>CTLR.CED is 0, then a corrected error event is defined as follows:
A corrected error event occurs when a counter overflows and sets a counter overflow flag to 1.
It is UNPREDICTABLE whether a corrected error event occurs when a software write sets a counter overflow flag to 1.
It is UNPREDICTABLE whether a corrected error event occurs when a counter overflows and the overflow flag was previously set to 1.
Otherwise, a corrected error event occurs when the error record records an error as a Corrected error.
The interrupt is generated even if the error syndrome is discarded because the error record already records a higher priority error.
The reset behavior of this field is:
Reserved, RES0.
In-band error response on writes enable.
When enabled, responses to writes that detect an error that is not corrected and is not deferred are signaled with an in-band error response (External abort).
It is IMPLEMENTATION DEFINED whether an uncorrected error that is deferred and recorded as Deferred error, but is not deferred to the Requester, will signal an in-band error response to the Requester.
WUE | Meaning |
---|---|
0b0 |
In-band error response for uncorrected errors on writes disabled. |
0b1 |
In-band error response for uncorrected errors on writes enabled. |
The reset behavior of this field is:
Reserved, RES0.
Fault handling interrupt on writes enable.
When enabled:
WFI | Meaning |
---|---|
0b0 |
Fault handling interrupt on writes disabled. |
0b1 |
Fault handling interrupt on writes enabled. |
See ERR<n>CTLR.CFI for more information on corrected error events.
The interrupt is generated even if the error syndrome is discarded because the error record already records a higher priority error.
The reset behavior of this field is:
Reserved, RES0.
Uncorrected error recovery interrupt on writes enable.
When enabled, the error recovery interrupt is generated for errors recorded as Uncorrected error on writes.
WUI | Meaning |
---|---|
0b0 |
Error recovery interrupt on writes disabled. |
0b1 |
Error recovery interrupt on writes enabled. |
The interrupt is generated even if the error syndrome is discarded because the error record already records a higher priority error.
The reset behavior of this field is:
Reserved, RES0.
In-band error response enable.
When ERR<n>FR.UE == 0b10, this control applies to errors arising from both reads and writes.
When enabled, responses to transactions that detect an error that is not corrected and is not deferred are signaled with an in-band error response (External abort).
It is IMPLEMENTATION DEFINED whether an uncorrected error that is deferred and recorded as Deferred error, but is not deferred to the Requester, will signal an in-band error response to the Requester.
UE | Meaning |
---|---|
0b0 |
In-band error response for uncorrected errors disabled. |
0b1 |
In-band error response for uncorrected errors enabled. |
The reset behavior of this field is:
In-band error response on reads enable.
When ERR<n>FR.UE == 0b11, this field is named RUE.
When enabled, responses to reads that detect an error that is not corrected and is not deferred are signaled with an in-band error response (External abort).
It is IMPLEMENTATION DEFINED whether an uncorrected error that is deferred and recorded as Deferred error, but is not deferred to the Requester, will signal an in-band error response to the Requester.
RUE | Meaning |
---|---|
0b0 |
In-band error response for uncorrected errors on reads disabled. |
0b1 |
In-band error response for uncorrected errors on reads enabled. |
The reset behavior of this field is:
Reserved, RES0.
Fault handling interrupt enable.
When ERR<n>FR.FI == 0b10, this control applies to errors on both reads and writes.
When enabled:
FI | Meaning |
---|---|
0b0 |
Fault handling interrupt disabled. |
0b1 |
Fault handling interrupt enabled. |
See ERR<n>CTLR.CFI for more information on corrected error events.
The interrupt is generated even if the error syndrome is discarded because the error record already records a higher priority error.
The reset behavior of this field is:
Fault handling interrupt on reads enable.
When ERR<n>FR.FI == 0b11, this field is named RFI.
When enabled:
RFI | Meaning |
---|---|
0b0 |
Fault handling interrupt on reads disabled. |
0b1 |
Fault handling interrupt on reads enabled. |
See ERR<n>CTLR.CFI for more information on corrected error events.
The interrupt is generated even if the error syndrome is discarded because the error record already records a higher priority error.
The reset behavior of this field is:
Reserved, RES0.
Uncorrected error recovery interrupt enable.
When ERR<n>FR.UI == 0b10, this control applies to errors arising from both reads and writes.
When enabled, the error recovery interrupt is generated for all errors recorded as Uncorrected error.
UI | Meaning |
---|---|
0b0 |
Error recovery interrupt disabled. |
0b1 |
Error recovery interrupt enabled. |
The interrupt is generated even if the error syndrome is discarded because the error record already records a higher priority error.
The reset behavior of this field is:
Uncorrected error recovery interrupt on reads enable.
When ERR<n>FR.UI == 0b11, this field is named RUI.
When enabled, the error recovery interrupt is generated for errors recorded as Uncorrected error on reads.
RUI | Meaning |
---|---|
0b0 |
Error recovery interrupt on reads disabled. |
0b1 |
Error recovery interrupt on reads enabled. |
The interrupt is generated even if the error syndrome is discarded because the error record already records a higher priority error.
The reset behavior of this field is:
Reserved, RES0.
Reserved for IMPLEMENTATION DEFINED controls. Must permit SBZP write policy for software.
Error reporting and logging enable. When disabled, the node behaves as if error detection and correction are disabled, and no errors are recorded or signaled by the node. Arm recommends that, when disabled, correct error detection and correction codes are written for writes, unless disabled by an IMPLEMENTATION DEFINED control for error injection.
ED | Meaning |
---|---|
0b0 |
Error reporting disabled. |
0b1 |
Error reporting enabled. |
It is IMPLEMENTATION DEFINED whether the node fully disables error detection and correction when reporting is disabled. That is, even with error reporting disabled, the node might continue to silently correct errors. Uncorrected errors might result in corrupt data being silently propagated by the node.
If this node requires initialization after Cold reset to prevent signaling false errors, then Arm recommends this field is set to 0 on Cold reset, meaning errors are not reported from Cold reset. This allows boot software to initialize a node without signaling errors. Software can enable error reporting after the node is initialized. Otherwise, the Cold reset value is IMPLEMENTATION DEFINED. If the Cold reset value is 1, the reset values of other controls in this register are also IMPLEMENTATION DEFINED and should not be UNKNOWN.
The reset behavior of this field is:
Reserved, RES0.
Component | Offset | Instance |
---|---|---|
RAS | 0x008 + (64 * n) | ERR<n>CTLR |
Accesses on this interface are RW.
26/03/2024 09:49; 67c0ae5282a7629ba0ea0ba7267b43cd4f7939f6
Copyright © 2010-2024 Arm Limited or its affiliates. All rights reserved. This document is Non-Confidential.