The GICD_ICENABLER<n> characteristics are:
Disables forwarding of the corresponding interrupt to the CPU interfaces.
These registers are available in all GIC configurations. If GICD_CTLR.DS==0, these registers are Common.
The number of implemented GICD_ICENABLER<n> registers is (GICD_TYPER.ITLinesNumber+1). Registers are numbered from 0.
GICD_ICENABLER0 is Banked for each connected PE with GICR_TYPER.Processor_Number < 8.
Accessing GICD_ICENABLER0 from a PE with GICR_TYPER.Processor_Number > 7 is CONSTRAINED UNPREDICTABLE:
GICD_ICENABLER<n> is a 32-bit register.
For SPIs and PPIs, controls the forwarding of interrupt number 32n + x to the CPU interfaces. Reads and writes have the following behavior:
Clear_enable_bit<x> | Meaning |
---|---|
0b0 | If read, indicates that forwarding of the corresponding interrupt is disabled. If written, has no effect. |
0b1 | If read, indicates that forwarding of the corresponding interrupt is enabled. If written, disables forwarding of the corresponding interrupt. After a write of 1 to this bit, a subsequent read of this bit returns 0. |
For SGIs, the behavior of this bit is IMPLEMENTATION DEFINED.
The reset behavior of this field is:
For INTID m, when DIV and MOD are the integer division and modulo operations:
Writing a 1 to a GICD_ICENABLER<n> bit only disables the forwarding of the corresponding interrupt from the Distributor to any CPU interface. It does not prevent the interrupt from changing state, for example becoming pending or active and pending if it is already active.
For SGIs and PPIs:
Bits corresponding to unimplemented interrupts are RAZ/WI.
When GICD_CTLR.DS==0, bits corresponding to Group 0 and Secure Group 1 interrupts are RAZ/WI to Non-secure accesses.
It is IMPLEMENTATION DEFINED whether implemented SGIs are permanently enabled, or can be enabled and disabled by writes to GICD_ISENABLER<n> and GICD_ICENABLER<n> where n=0.
Completion of a write to this register does not guarantee that the effects of the write are visible throughout the affinity hierarchy. To ensure an enable has been cleared, software must write to the register with bits set to 1 to clear the required enables. Software must then poll GICD_CTLR.RWP until it has the value zero.
Component | Frame | Offset | Instance |
---|---|---|---|
GIC Distributor | Dist_base | 0x0180 + (4 * n) | GICD_ICENABLER<n> |
Accesses on this interface are RW.
26/03/2024 09:49; 67c0ae5282a7629ba0ea0ba7267b43cd4f7939f6