The MSMON_CFG_MBWU_CTL characteristics are:

Purpose

Controls the MBWU monitor selected by MSMON_CFG_MON_SEL.

MSMON_CFG_MBWU_CTL_s controls the Secure memory bandwidth usage monitor instance selected by the Secure instance of MSMON_CFG_MON_SEL. MSMON_CFG_MBWU_CTL_ns controls Non-secure memory bandwidth usage monitor instance selected by the Non-secure instance of MSMON_CFG_MON_SEL. MSMON_CFG_MBWU_CTL_rt controls the monitor configuration for the Root PARTID selected by the Root instance of MSMON_CFG_MON_SEL. MSMON_CFG_MBWU_CTL_rl controls the monitor configuration for the Realm PARTID selected by the Realm instance of MSMON_CFG_MON_SEL.

If MPAMF_IDR.HAS_RIS is 1, the monitor instance configuration accessed is for the resource instance currently selected by MSMON_CFG_MON_SEL.RIS and the monitor instance of that resource instance selected by MSMON_CFG_MON_SEL.MON_SEL.

Configuration

The power domain of MSMON_CFG_MBWU_CTL is IMPLEMENTATION DEFINED.

This register is present only when FEAT_MPAM is implemented, MPAMF_IDR.HAS_MSMON == 1 and MPAMF_MSMON_IDR.MSMON_MBWU == 1. Otherwise, direct accesses to MSMON_CFG_MBWU_CTL are RES0.

The power and reset domain of each MSC component is specific to that component.

Attributes

MSMON_CFG_MBWU_CTL is a 32-bit register.

Field descriptions

313029282726252423222120191817161514131211109876543210
ENCAPT_EVNTCAPT_RESETOFLOW_STATUSOFLOW_INTROFLOW_FRZOFLOW_CAPTSUBTYPESCLENCEVNT_OFLWMATCH_PMGMATCH_PARTIDOFLOW_STATUS_LOFLOW_INTR_LOFLOW_CAPT_LRES0OFLOW_LNKGTYPE

EN, bit [31]

Enabled.

ENMeaning
0b0

The monitor instance is disabled and must not collect any information.

0b1

The monitor instance is enabled to collect information according to the configuration of the instance.

CAPT_EVNT, bits [30:28]

Capture event selector.

When the selected capture event occurs, MSMON_MBWU of the monitor instance is copied to MSMON_MBWU_CAPTURE of the same instance. If the long counter is also implemented, MSMON_MBWU_L is also copied to MSMON_MBWU_L_CAPTURE.

Select the event that triggers capture from the following:

CAPT_EVNTMeaning
0b000

No capture event is triggered.

0b001

External capture event 1 (optional, but recommended)

0b010

External capture event 2 (optional)

0b011

External capture event 3 (optional)

0b100

External capture event 4 (optional)

0b101

External capture event 5 (optional)

0b110

External capture event 6 (optional)

0b111

Capture occurs when a MSMON_CAPT_EVNT register in this MSC is written and causes a capture event for the Security state of this monitor. (optional)

The values marked as optional indicate capture event sources that can be omitted in an implementation. Those values representing non-implemented event sources must not trigger a capture event.

When MPAMF_MBWUMON_IDR.HAS_CAPTURE == 0, access to this field is RAZ/WI.

CAPT_RESET, bit [27]

Reset MSMON_MBWU.VALUE after capture.

Controls whether the VALUE field of the monitor instance is reset to zero immediately after being copied to the corresponding capture register.

CAPT_RESETMeaning
0b0

MSMON_MBWU.VALUE field of the monitor instance is not reset on capture.

0b1

MSMON_MBWU.VALUE field of the monitor instance is reset on capture.

This control bit affects both MSMON_MBWU and MSMON_MBWU_L in implementations that include MSMON_MBWU_L.

When MPAMF_MBWUMON_IDR.HAS_CAPTURE == 0, access to this field is RAZ/WI.

OFLOW_STATUS, bit [26]

Overflow status.

Indicates whether the value of MSMON_MBWU has overflowed.

OFLOW_STATUSMeaning
0b0

MSMON_MBWU.VALUE has not overflowed.

0b1

MSMON_MBWU.VALUE has overflowed at least once since this bit was last written to zero.

Overflow status for MSMON_MBWU_L.VALUE is reported in MSMON_CFG_MBWU_CTL.OFLOW_STATUS_L.

If MPAMF_MBWUMON_IDR.HAS_CEVNT_OFLW is 1 or MPAMF_MBWUMON_IDR.HAS_OFLOW_LNKG is 1, then a store to MSMON_MBWU when this field is 1 resets this field to 0.

OFLOW_INTR, bit [25]

Enable interrupt on overflow of MSMON_MBWU.VALUE.

OFLOW_INTRMeaning
0b0

No interrupt is signaled on an overflow of MSMON_MBWU.VALUE.

0b1

An implementation-specific interrupt is signaled on an overflow of MSMON_MBWU.VALUE.

Interrupt enable for overflow of MSMON_MBWU_L.VALUE is controlled by MSMON_CFG_MBWU_CTL.OFLOW_INTR_L.

When MSMON_CFG_MBWU_CTL.OFLOW_INTR == 0, access to this field is RAZ/WI.

OFLOW_FRZ, bit [24]

Freeze monitor instance on overflow.

Controls whether MSMON_MBWU.VALUE field of the monitor instance freezes on an overflow.

OFLOW_FRZMeaning
0b0

MSMON_MBWU.VALUE field of the monitor instance wraps on overflow.

0b1

MSMON_MBWU.VALUE field of the monitor instance freezes on overflow. If the increment that caused the overflow was 1, the frozen value is the post-increment value of 0. If the increment that caused the overflow was larger than 1, the frozen value of the monitor might be 0 or a larger value less than the final increment.

When a MSMON_MBWU.VALUE of a monitor instance is frozen it does not change until MSMON_CSU register for that instance has been written. If the monitor implements both MSMON_MBWU and MSMON_MBWU_L registers, both are frozen. A write to a frozen register unfreezes the count for just that register.

This control bit affects both MSMON_MBWU and MSMON_MBWU_L in implementations that include MSMON_MBWU_L.

OFLOW_CAPT, bit [23]
When (FEAT_MPAMv0p1 is implemented or FEAT_MPAMv1p1 is implemented) and MPAMF_MBWUMON_IDR.HAS_OFLOW_CAPT == 1:

Capture Monitor on Overflow.

OFLOW_CAPTMeaning
0b0

Monitor register MSMON_MBWU is not captured on an overflow or when affected by an overflow linkage event.

0b1

Monitor register MSMON_MBWU is captured and the MSMON_MBWU.{NRDY, VALUE} fields are copied to the monitor instance's MSMON_MBWU_CAPTURE register on an overflow or when affected by an overflow linkage event. The monitor instance treats an overflow of this monitor instance as a private capture event. If MSMON_CFG_MBWU_CTL.CEVNT_OFLW is 1, this monitor instance also treats an overflow linkage event as a capture event.

If OFLOW_FRZ is 1, the monitor does not continue to count after the overflow or overflow linkage event. If CAPT_RESET is 1, the monitor instance resets to 0.

This bit does not control whether MSMON_MBWU_L is captured on an overflow or overflow linkage event. See MSMON_CFG_MBWU_CTL.OFLOW_CAPT_L.


Otherwise:

Reserved, RES0.

SUBTYPE, bits [22:20]

Subtype. Type of bandwidth counted by this monitor.

This field is not currently used for MBWU monitors, but reserved for future use.

This field is RAZ/WI.

SCLEN, bit [19]

MSMON_MBWU.VALUE Scaling Enable.

Enables scaling of MSMON_MBWU.VALUE by MPAMF_MBWUMON_IDR.SCALE.

SCLENMeaning
0b0

MSMON_MBWU.VALUE has bytes counted by the monitor instance.

0b1

MSMON_MBWU.VALUE has bytes counted by the monitor instance, shifted right by MPAMF_MBWUMON_IDR.SCALE.

CEVNT_OFLW, bit [18]
When (FEAT_MPAMv0p1 is implemented or FEAT_MPAMv1p1 is implemented) and MPAMF_MBWUMON_IDR.HAS_CEVNT_OFLW == 1:

Capture Event performs overflow behavior.

CEVNT_OFLWMeaning
0b0

On a capture event matching the CAPT_EVNT field the capture behaviors are performed.

The NRDY and VALUE fields are transferred to the monitor instance's capture register.

0b1

On a capture event matching the CAPT_EVNT field the monitor instance treats a capture event as an overflow and the overflow behaviors are performed.

The behavior is controlled by the MSMON_CFG_MBWU_CTL.{OFLOW_FRZ, OFLOW_CAPT, OFLOW_CAPT_L, CAPT_RESET} fields. The MSMON_CFG_MBWU_CTL.{OFLOW_STATUS, OFLOW_STATUS_L} fields are set for this monitor instance.


Otherwise:

Reserved, RES0.

MATCH_PMG, bit [17]

Match PMG.

Controls whether the monitor instance only counts data transferred with PMG matching MSMON_CFG_MBWU_FLT.PMG.

MATCH_PMGMeaning
0b0

The monitor instance counts data transferred with any PMG value.

0b1

The monitor instance only counts data transferred with the PMG value matching MSMON_CFG_MBWU_FLT.PMG.

MATCH_PARTID, bit [16]

Match PARTID.

Controls whether the monitor instance counts only data transferred with PARTID matching MSMON_CFG_MBWU_FLT.PARTID.

MATCH_PARTIDMeaning
0b0

The monitor instance counts data transferred with any PARTID value.

0b1

The monitor instance only counts data transferred with the PARTID value matching MSMON_CFG_MBWU_FLT.PARTID.

OFLOW_STATUS_L, bit [15]
When FEAT_MPAMv0p1 is implemented or FEAT_MPAMv1p1 is implemented:

Overflow Status of MSMON_MBWU_L.VALUE of the monitor instance.

Indicates whether MSMON_MBWU_L.VALUE has overflowed.

OFLOW_STATUS_LMeaning
0b0

MSMON_MBWU_L.VALUE has not overflowed.

0b1

MSMON_MBWU_L.VALUE has overflowed at least once since this bit was last written to zero.

If MPAMF_MBWUMON_IDR.HAS_LONG == 0, this bit is RES0.

Overflow status of MSMON_MBWU.VALUE is reported in MSMON_CFG_MBWU_CTL.OFLOW_STATUS.

If MPAMF_MBWUMON_IDR.HAS_CEVNT_OFLW is 1 or MPAMF_MBWUMON_IDR.HAS_OFLOW_LNKG is 1, then a store to MSMON_MBWU_L when this field is 1 resets this field to 0.


Otherwise:

Reserved, RES0.

OFLOW_INTR_L, bit [14]
When (FEAT_MPAMv0p1 is implemented or FEAT_MPAMv1p1 is implemented) and MPAMF_MBWUMON_IDR.HAS_LONG == 1:

Overflow Interrupt for MSMON_MBWU_L.

Controls whether an MPAM overflow interrupt is generated when MSMON_MBWU_L.VALUE overflows.

OFLOW_INTR_LMeaning
0b0

No interrupt is signaled on an overflow of MSMON_MBWU_L.VALUE.

0b1

An implementation-specific interrupt is signaled on overflow of MSMON_MBWU_L.VALUE.

When MSMON_CFG_MBWU_CTL.OFLOW_INTR_L == 0, access to this field is RAZ/WI.


Otherwise:

Reserved, RES0.

OFLOW_CAPT_L, bit [13]
When (FEAT_MPAMv0p1 is implemented or FEAT_MPAMv1p1 is implemented), MPAMF_MBWUMON_IDR.HAS_LONG == 1 and MPAMF_MBWUMON_IDR.HAS_OFLOW_CAPT == 1:

Capture Long Monitor on Overflow.

Controls whether MSMON_MBWU_L is copied to MSMON_MBWU_L_CAPTURE on an overflow or an overflow linkage event.

OFLOW_CAPT_LMeaning
0b0

Monitor register MSMON_MBWU_L is not captured on an overflow or when affected by an overflow linkage event.

0b1

Monitor register MSMON_MBWU_L is captured on an overflow or when affected by an overflow linkage event. If OFLOW_FRZ is 1, the monitor does not continue to count after the overflow or overflow linkage event. If CAPT_RESET is 1, the monitor instance resets to 0.

If this bit is 1, this monitor instance treats an overflow of this monitor instance as a private capture event.

If this bit is 1, this monitor instance also treats overflow linkage events for which it qualifies as a private capture event.


Otherwise:

Reserved, RES0.

Bits [12:11]

Reserved, RES0.

OFLOW_LNKG, bits [10:8]
When (FEAT_MPAMv0p1 is implemented or FEAT_MPAMv1p1 is implemented) and MPAMF_MBWUMON_IDR.HAS_OFLOW_LNKG == 1:

Overflow linkage event.

Controls signaling of a capture event on overflow of this monitor instance.

OFLOW_LNKGMeaning
0b000

Overflow of the monitor instance only affects this monitor instance.

0b001

Overflow of this monitor instance signals Capture Event 1.

0b010

Overflow of this monitor instance signals Capture Event 2.

0b011

Overflow of this monitor instance signals Capture Event 3.

0b100

Overflow of this monitor instance signals Capture Event 4.

0b101

Overflow of this monitor instance signals Capture Event 5.

0b110

Overflow of this monitor instance signals Capture Event 6.

0b111

Reserved.


Otherwise:

Reserved, RES0.

TYPE, bits [7:0]

Monitor Type Code. The MBWU monitor is TYPE = 0x42.

TYPE is a read-only constant indicating the type of the monitor.

Reads as 0x42.

Access to this field is RO.

Accessing MSMON_CFG_MBWU_CTL

This register is within the MPAM feature page memory frames.

In a system that supports Secure, Non-secure, Root, and Realm memory maps, there must be MPAM feature pages in all four address maps:

MSMON_CFG_MBWU_CTL_s, MSMON_CFG_MBWU_CTL_ns, MSMON_CFG_MBWU_CTL_rt, and MSMON_CFG_MBWU_CTL_rl must be separate registers:

When RIS is implemented, loads and stores to MSMON_CFG_MBWU_CTL access the monitor configuration settings for the bandwidth resource instance selected by MSMON_CFG_MON_SEL.RIS and the memory bandwidth usage monitor instance selected by MSMON_CFG_MON_SEL.MON_SEL.

When RIS is not implemented, loads and stores to MSMON_CFG_MBWU_CTL access the monitor configuration settings for the memory bandwidth usage monitor instance selected by MSMON_CFG_MON_SEL.MON_SEL.

MSMON_CFG_MBWU_CTL can be accessed through the memory-mapped interfaces:

ComponentFrameOffsetInstance
MPAMMPAMF_BASE_s0x0828MSMON_CFG_MBWU_CTL_s

Accesses on this interface are RW.

ComponentFrameOffsetInstance
MPAMMPAMF_BASE_ns0x0828MSMON_CFG_MBWU_CTL_ns

Accesses on this interface are RW.

ComponentFrameOffsetInstance
MPAMMPAMF_BASE_rt0x0828MSMON_CFG_MBWU_CTL_rt

When FEAT_RME is implemented, accesses on this interface are RW.

ComponentFrameOffsetInstance
MPAMMPAMF_BASE_rl0x0828MSMON_CFG_MBWU_CTL_rl

When FEAT_RME is implemented, accesses on this interface are RW.